| Fibre type | PM 630_125-12/250_C | PM 850_125-12/250_C | PM 980_125-12/250_C | PM 1310_125-13/250_C | PM 14xx_125-13/250_C | PM 1550_125-13/250_C | |
|---|---|---|---|---|---|---|---|
| Part No. | PM1011-A+ | PM1012-A+ | PM1015-A+ | PM1016-C+ | PM1018-A+ | PM1017-C+ | |
| Optical properties | |||||||
| Operating wavelength (nm) | 630 | 850 | 980 | 1310 | 1400 ~ 1490 | 1550 | |
| Fibre cutoff wavelength (nm) | 520 ~ 620 | 650 ~ 800 | 800 ~ 970 | 1100 ~ 1290 | 1200 ~ 1380 | 1290 ~ 1520 | |
| Mode field diameter (μm) | 4.5±0.5@630nm | 5.5±0.5@850nm | 6.5±0.5@980nm | 9.0±0.5@1310nm | 9.8±0.5@1450nm | 10.5±0.5@1550nm | |
| Attenuation (dB/km) | ≤15.0 | ≤3.0 | ≤2.5 | ≤0.5 | ≤0.5 | ≤0.5 | |
| Beat length (mm) | ≤3.0 | 2.5 ~ 4.5 | 3.0 ~ 5.0 | 3.5 ~ 6.5 | 4.0 ~ 7.5 | 4.5 ~ 8.0 | |
| Polarization crosstalk@ 4m (dB) | ≤-25@630nm | ≤-25@850nm | ≤-25@980nm | ≤-30@1310nm | ≤-30@14xxnm | ≤-30@1550nm | |
| Polarization crosstalk@ 100 m (dB) | ≤-25@630nm | ≤-25@850nm | ≤-25@980nm | ≤-25@1310nm | ≤-25@14xxnm | ≤-25@1550nm | |
| Geometrical properties | |||||||
| Cladding diameter (μm) | 124.5±1.0 | 124.5±1.0 | 124.5±1.0 | 124.5±1.0 | 124.5±1.0 | 124.5±1.0 | |
| Coating diameter (μm) | 245.0±5.0 | 245.0±5.0 | 245.0±5.0 | 245.0±5.0 | 245.0±5.0 | 245.0±5.0 | |
| Cladding non-circularity (%) | ≤2.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | |
| Core/cladding concentricity error (μm) | ≤0.5 | ≤0.5 | ≤0.5 | ≤0.5 | ≤0.5 | ≤0.5 | |
| Coating material | Dual-layer, UV-cured acrylate | Dual-layer, UV-cured acrylate | Dual-layer, UV-cured acrylate | Dual-layer, UV-cured acrylate | Dual-layer, UV-cured acrylate | Dual-layer, UV-cured acrylate | |
| Mechanical performance | |||||||
| Operating temperature range (°C) | -45 ~ 85 | -45 ~ 85 | -45 ~ 85 | -45 ~ 85 | -45 ~ 85 | -45 ~ 85 | |
| Proof test level (kpsi) | 100 | 100 | 100 | 100 | 100 | 100 | |
| Fibre length (m) | Customer-specified | Customer-specified | Customer-specified | Customer-specified | Customer-specified | Customer-specified | |
These PM-specific measurements are different from general cable qualification tests such as attenuation, insertion loss, OTDR analysis, tensile testing, and environmental testing. Hengtong's overview of fiber-optic cable testing explains those broader optical and mechanical test categories.
In many of these systems, choosing the fiber is only one part of the design. The complete optical path must also preserve axis orientation through pigtails, connectors, splices, couplers, and other components.