Cable Section Design
Application
- ✰ Long-distance backbone network
- ✰ Urban ring network
- ✰ Access Network, FTTX
- ✰ Relay between communication machine rooms
- ✰ Building cable in integrated wiring
Main Feature
- Good mechanical and temperature performance
- High strength loose tube that is hydrolysis resistant
- Special tube filling compound ensure a critical protection of fiber
- Specially designed compact structure is good at preventing loose tubes from shrinking
- PE sheath protects cable from ultraviolet radiation
- The following measures are taken to ensure the cable watertight:
- Single Fiber Reinforced Plastic as the central strength member
- Loose tube filling compound
- 100% cable core filling
- APL moisture barrier
Standards
Comply with standard YD/T 901-2009 as well as IEC 60794-1
Optical Characteristics
G.652 |
G.655 |
50/125μm |
62.5/125μm |
||
Attenuation (+20℃) |
@850nm |
|
|
≤3.0 dB/km |
≤3.0 dB/km |
@1300nm |
|
|
≤1.0 dB/km |
≤1.0 dB/km |
|
@1310nm |
≤0.36 dB/km |
≤0.40 dB/km |
|
|
|
@1550nm |
≤0.22 dB/km |
≤0.23dB/km |
|
|
|
Bandwidth (Class A) |
@850nm |
|
|
≥500 MHz·km |
≥200 MHz·km |
@1300nm |
|
|
≥1000 MHz·km |
≥600 MHz·km |
|
Numerical Aperture |
|
|
0.200±0.015NA |
0.275±0.015NA |
|
Cable Cut-off Wavelength |
≤1260nm |
≤1480nm |
|
|
GYFTA Cable Technical Parameters
Cable Type |
Fiber Count |
Tubes |
Fillers |
Cable Diameter mm |
Cable Weight kg/km |
Tensile Strength Long/Short Term N |
Crush Resistance Long/Short Term N/100mm |
Bending Radius Static/Dynamic mm |
GYFTS-2~6 |
2~6 |
1 |
5 |
11.4 |
108 |
400/1000 |
300/1000 |
10D/20D |
GYFTS-8~12 |
8~12 |
2 |
4 |
11.4 |
108 |
400/1000 |
300/1000 |
10D/20D |
GYFTS-14~18 |
14~18 |
3 |
3 |
11.4 |
108 |
400/1000 |
300/1000 |
10D/20D |
GYFTS-20~24 |
20~24 |
4 |
2 |
11.4 |
108 |
400/1000 |
300/1000 |
10D/20D |
GYFTS-26~30 |
26~30 |
5 |
1 |
11.4 |
108 |
400/1000 |
300/1000 |
10D/20D |
GYFTS-32~36 |
32~36 |
6 |
0 |
11.4 |
108 |
400/1000 |
300/1000 |
10D/20D |
GYFTS-2~12 |
2~12 |
1 |
5 |
12.8 |
134 |
600/1500 |
300/1000 |
10D/20D |
GYFTS-14~24 |
14~24 |
2 |
4 |
12.8 |
134 |
600/1500 |
300/1000 |
10D/20D |
GYFTS-26~36 |
26~36 |
3 |
3 |
12.8 |
134 |
600/1500 |
300/1000 |
10D/20D |
GYFTS-38~48 |
38~48 |
4 |
2 |
12.8 |
134 |
600/1500 |
300/1000 |
10D/20D |
GYFTS-50~60 |
50~60 |
5 |
1 |
12.8 |
134 |
600/1500 |
300/1000 |
10D/20D |
GYFTS-62~72 |
62~72 |
6 |
0 |
12.8 |
134 |
600/1500 |
300/1000 |
10D/20D |
GYFTS-2~6 |
2~6 |
1 |
7 |
12.8 |
140 |
1000/3000 |
300/1000 |
10D/20D |
GYFTS-8~12 |
8~12 |
2 |
6 |
12.8 |
140 |
1000/3000 |
300/1000 |
10D/20D |
GYFTS-14~18 |
14~18 |
3 |
5 |
12.8 |
140 |
1000/3000 |
300/1000 |
10D/20D |
GYFTS-20~24 |
20~24 |
4 |
4 |
12.8 |
140 |
1000/3000 |
300/1000 |
10D/20D |
GYFTS-26~30 |
26~30 |
5 |
3 |
12.8 |
140 |
1000/3000 |
300/1000 |
10D/20D |
GYFTS-32~36 |
32~36 |
6 |
2 |
12.8 |
140 |
1000/3000 |
300/1000 |
10D/20D |
GYFTS-38~42 |
38~42 |
7 |
1 |
12.8 |
140 |
1000/3000 |
300/1000 |
10D/20D |
GYFTS-44~48 |
44~48 |
8 |
0 |
12.8 |
140 |
1000/3000 |
300/1000 |
10D/20D |
GYFTS-50~60 |
50~60 |
5 |
3 |
14.8 |
176 |
1000/3000 |
300/1000 |
10D/20D |
GYFTS-62~72 |
62~72 |
6 |
2 |
14.8 |
176 |
1000/3000 |
300/1000 |
10D/20D |
GYFTS-74~84 |
74~84 |
7 |
1 |
14.8 |
176 |
1000/3000 |
300/1000 |
10D/20D |
GYFTS-86~96 |
86~96 |
8 |
0 |
14.8 |
176 |
1000/3000 |
300/1000 |
10D/20D |
GYFTS-98~108 |
98~108 |
9 |
1 |
17.1 |
226 |
1000/3000 |
300/1000 |
10D/20D |
GYFTS-110~120 |
110~120 |
10 |
0 |
17.1 |
226 |
1000/3000 |
300/1000 |
10D/20D |
GYFTS-122~132 |
122~132 |
11 |
1 |
19.2 |
279 |
1000/3000 |
300/1000 |
10D/20D |
GYFTS-134~144 |
134~144 |
12 |
0 |
19.2 |
279 |
1000/3000 |
300/1000 |
10D/20D |
Environmental Characteristics
- Transport/storage temperature: -40℃ to +70℃
- Compound flow: No filling compound or coating compound drop out of optical cable at 70℃
- Water penetration: No water comes out within 24 hours after 1m water head is applied to the entire cross section of 3m long optical cable